EAPL A1D1-X 60 M Electronic Timer
Product Details :
Function
A1D1-X (60M) is an ON Delay Timer. On the Power application, preset timing starts and at the end of the timing 2C/O relay contacts change over and remain in this state till the power is interrupted.
Contact Rating
- Terminal block
- Slide switches for range selection
- Relay status LED
- Time Tuning Pot
- Range Viewing Window
- Select the range with the help of 2 slide switches on the side panel. The selected range can be seen in the windows on the front panel.
- Set the required time by gently rotating the Front pot with a suitable screwdriver. Apply rated voltage across A1 and A2 terminals.
- The LED glows and the time starts. After the set time the LED goes off and relay contact changes from NC to NO.
- Relay contacts remain in the same position, till power is interrupted.
- Do not change the time range & set time while the timer is in operation.
- Switch off the power while changing the time range and set time.
- Application of voltage other than the specified one will permanently damage the timer.
- Do not forcibly rotate the pot. It will damage the timer.
- 24 To 240V AC, 50/60Hz
- 24 To 220V DC, -10% To +10%
- 250 V AC/28 V DC Resistive Road
- 6 to 60 Sec
- 6 to 66 mins
EATON XEFFECT FAZ-D10/3 Electrical Fuse
GEA Westfalla Seprator AG
General Electric G62B10 B6 C6 mcb Switch
Brand : General Electric
Product Type : MCB
Model : G62B10
AC/DC : AC
Rated Current : 10A
Pole :2P
Breaking Capacity :6kA
Curve :B
Module Nr. :2
Weight :0.24kg
Dimensions (WxLxH) : 3.6x6.8x8.6cm
Additional equipment possible: Yes
Ambient temperature during operating: -25 - 70°C
Built-in depth: 44mm
Concurrently switching N-neutral: No
Connectable conductor cross section multi-wired: 0.75 - 25mm²
Connectable conductor cross section solid-core: 1 - 35mm²
Current limiting class: 3
Degree of protection (IP): IP20
ETIM Class: Miniature circuit breaker (MCB)
ETIM Group: Circuit breakers and fuses
Frequency: 50 - 60Hz
Number of poles (total): 2
Number of protected poles: 2
Over voltage category: 3
Pollution degree: 2
Rated current: 10A
Rated impulse withstand voltage Uimp: 6kV
Rated insulation voltage Ui: 500V
Rated voltage: 400V
Release characteristic: B
Suitable for flush-mounted installation: No
Voltage type: AC
Width in number of modular spacings: 2
Hager MCB 10 Amp Single Pole Circuit Breaker
Miniature Circuit Breakers (MCBs) are electromechanical devices that are used to protect an electrical circuit from an overcurrent. The lead reason for an overcurrent could be a short circuit or overload. Unlike a Fuse, MCB does not have to be replaced every time a fault occurs and it can be reused.
Hager NCN316A MCB 16A 10kA TP Type C
Hager NCN316A MCB 16A Triple Pole Type C 10kA is designed to provide comprehensive circuit protection solutions and protection.
Features
- MCB's are designed to detect over currents due to both overloads and faults
- Dolly Switch Design with on/off indicator
- DIN Rail Mounted
- Triple Module Space
- 10kA Short Circuit Protection
Hager NCN332N 32A C-Curve 10kA 3 Pole MCB
This 32A Three Pole C-Curve 10kA Miniature Circuit Breaker from the house of Hager is an innovatively designed MCB that protects an electric circuit from any sort of damage caused by overloading or short circuits. So, anytime there is a spike in line voltage or a sudden increase in line current, then this MCB will trip, causing the circuit/power to break, thereby eliminating any associated damage to the connected appliance/load.